York Error Codes
Inverter Mini-Splits & Air Conditioners ยท USA
Prefixes: E=System/Sensor, F=Sensor/Protection, P=Protection, H=Status
E-Series (System/Sensor Errors)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| E0 | EEPROM malfunction | EEPROM data error | Reset power; replace PCB if persists |
| E1 | Indoor/outdoor communication error | Communication line fault | Check signal wiring and connectors |
| E2 | Zero crossing signal error | Power supply issue | Check power supply voltage and frequency |
| E3 | Indoor fan speed error | Fan motor abnormal | Check fan motor and driver circuit |
| E4 | Room temperature sensor open/short | T1 sensor fault | Check and replace room sensor |
| E5 | Indoor coil sensor open/short | T2 sensor fault | Check and replace coil sensor |
| E6 | Outdoor coil sensor fault | Outdoor thermistor failure | Check outdoor coil temperature sensor |
| E7 | Outdoor discharge sensor fault | Discharge thermistor open or short | Check compressor discharge sensor |
| E8 | Outdoor ambient sensor fault | Outdoor temperature sensor failure | Check outdoor ambient thermistor |
| EC | Refrigerant leak detected | Leak sensor triggered | Check for leaks, repair and recharge |
F-Series (Sensor/Protection Codes)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| F1 | Condenser high temperature protection | Condenser coil overheating | Clean condenser, check fan operation |
| F2 | Evaporator freeze protection | Evaporator coil freezing | Check airflow, filter, refrigerant charge |
| F3 | Discharge temperature protection | High discharge temperature | Check superheat and refrigerant charge |
| F4 | Compressor overload protection | Compressor overcurrent | Check compressor and power supply |
H-Series (Status/Protection)
P-Series (Protection Codes)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| P0 | IPM overcurrent protection | Inverter overcurrent | Check compressor and inverter board |
| P1 | High/low voltage protection | Supply voltage abnormal | Check voltage at outdoor unit |
| P2 | Compressor overheating protection | Compressor top temperature high | Check superheat, charge, airflow |
| P4 | Compressor drive error | Inverter drive fault | Check inverter board, compressor wiring |
No matching error codes found
Try a different search term or browse the categories above.
York Troubleshooting Tips
Before Calling for Service
- Turn off unit, wait 5 minutes, then restart - some errors auto-reset
- Check and clean air filters - many errors caused by restricted airflow
- Verify power supply voltage is within specification
- Check circuit breaker and disconnect switch
- Note the exact error code and when it occurs for technician