Trane Error Codes
Inverter Mini-Splits & Air Conditioners ยท USA
Prefixes: E=System/Sensor, F=Sensor/Protection, P=Protection, H=Status
E-Series (System/Sensor Errors)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| E0 | EEPROM parameter error | Unit EEPROM data corrupted | Reset power; replace PCB if persists |
| E1 | Indoor/outdoor communication error | Communication line disconnected | Check signal wiring between units |
| E2 | Zero crossing detection error | Power supply frequency abnormal | Check power supply quality |
| E3 | Fan speed out of control | Indoor fan motor abnormal | Check fan motor, capacitor, driver |
| E4 | Room temperature sensor fault | T1 thermistor open or short | Check and replace room sensor |
| E5 | Evaporator coil sensor fault | T2 thermistor open or short | Check and replace coil sensor |
| E6 | Condenser coil sensor fault | Outdoor coil thermistor fault | Check outdoor coil temperature sensor |
| E109 | Communication timeout during startup | Indoor-outdoor communication failed at startup | Verify all wiring and power connections |
| E201 | Indoor/outdoor tracking communication error | Indoor unit powered off or wire break | Check indoor power and daisy-chain wiring |
| E320 | OLP sensor open or short | Compressor top sensor or circuit board defective | Check OLP sensor, replace PCB if needed |
F-Series (Sensor/Protection Codes)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| F1 | Outdoor ambient sensor fault | Outdoor temperature sensor failure | Check outdoor ambient thermistor |
| F2 | Condenser temperature sensor fault | Condenser coil thermistor failure | Check condenser sensor resistance |
| F3 | Discharge temperature sensor fault | Compressor discharge thermistor failure | Check discharge temperature sensor |
H-Series (Status/Protection)
P-Series (Protection Codes)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| P0 | IPM module protection | Inverter module fault | Check IPM module and compressor |
| P1 | Over/under voltage protection | Supply voltage out of range | Check power supply voltage at unit |
| P2 | Compressor top temperature high | Compressor discharge overheating | Check superheat, charge, clean condenser |
| P4 | Inverter compressor drive error | Drive board failure | Check inverter drive board |
| P5 | DC fan motor fault | Outdoor fan motor feedback error | Check DC fan motor wiring and bearings |
No matching error codes found
Try a different search term or browse the categories above.
Trane Troubleshooting Tips
Before Calling for Service
- Turn off unit, wait 5 minutes, then restart - some errors auto-reset
- Check and clean air filters - many errors caused by restricted airflow
- Verify power supply voltage is within specification
- Check circuit breaker and disconnect switch
- Note the exact error code and when it occurs for technician