H
Hisense Error Codes
Inverter Mini-Splits & Air Conditioners ยท China
Prefixes: E=System/Sensor, F=Sensor/Protection, P=Protection, H=Status
E-Series (System/Sensor Errors)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| E0 | EEPROM error | EEPROM data fault | Reset power; replace PCB if persists |
| E1 | Indoor/outdoor communication error | Signal wiring fault | Check communication wiring |
| E2 | Zero crossing error | Power supply issue | Check power supply quality |
| E3 | Fan speed error | Indoor fan abnormal | Check fan motor and circuit |
| E4 | Room temperature sensor fault | T1 sensor open/short | Check room temperature sensor |
| E5 | Evaporator sensor fault | T2 sensor open/short | Check evaporator sensor |
| E6 | Condenser sensor fault | Outdoor coil sensor fault | Check condenser sensor |
| E8 | Duplex communication error | Address conflict | Reset unit addresses |
| EC | Refrigerant leak detected | Leak sensor triggered | Check for leaks, repair, recharge |
F-Series (Sensor/Protection Codes)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| F0 | Outdoor EEPROM error | Outdoor EEPROM fault | Reset; replace outdoor PCB if needed |
| F1 | Outdoor ambient sensor fault | T4 thermistor failure | Check outdoor ambient sensor |
| F2 | Condenser sensor fault | Condenser thermistor failure | Check condenser temperature sensor |
| F3 | Discharge sensor fault | Discharge thermistor failure | Check discharge temperature sensor |
| F4 | Suction sensor fault | Suction thermistor failure | Check suction line sensor |
P-Series (Protection Codes)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| P0 | IPM module protection | Inverter overcurrent | Check IPM module and compressor |
| P1 | Voltage protection | Voltage out of range | Check power supply voltage |
| P2 | Compressor overheating | Compressor discharge temp high | Check superheat, charge, airflow |
| P3 | Overcurrent protection | System drawing excess current | Check compressor and wiring |
| P4 | Inverter drive error | Drive board fault | Check inverter drive board |
| P5 | DC fan motor fault | Fan motor feedback error | Check outdoor DC fan motor |
No matching error codes found
Try a different search term or browse the categories above.
Hisense Troubleshooting Tips
Before Calling for Service
- Turn off unit, wait 5 minutes, then restart - some errors auto-reset
- Check and clean air filters - many errors caused by restricted airflow
- Verify power supply voltage is within specification
- Check circuit breaker and disconnect switch
- Note the exact error code and when it occurs for technician