Pressure-Temperature Charts

Saturation P-T data for common refrigerants

R-600a

Pure
GWP: 3
ODP: 0
Safety Class: A3

Natural refrigerant common in domestic refrigerators. Lower working pressure than R-290. Charge limits apply per IEC 60335-2-89.

A3 HIGHLY FLAMMABLE - Safety Warning

  • ASHRAE 34 Classification: A3 - Non-toxic but HIGHLY FLAMMABLE
  • Maximum charge limits: 150g (sealed systems) per IEC 60335-2-89
  • Use only explosion-proof equipment and tools
  • Work in well-ventilated areas - gas is heavier than air
  • No open flames, sparks, or hot surfaces during service
  • Use hydrocarbon-rated recovery equipment and leak detectors
  • Most domestic refrigerators contain 50-100g charge
Flammability Range: LEL 1.8% - UEL 8.4% in air

Quick P-T Lookup

kPa

* Results are interpolated from the P-T table data

Pressure Units: psig = Gauge pressure (relative to atmosphere) kPa / bar / kgf/cm² = Absolute pressure

°C °F kPa
-50 -58 13.0
-45 -49 19.0
-40 -40 26.0
-35 -31 35.0
-30 -22 47.0
-25 -13 61.0
-20 -4 78.0
-15 5 99.0
-12 10 115.0
-10 14 124.0
-5 23 154.0
0 32 189.0
5 41 230.0
10 50 278.0
15 59 333.0
20 68 396.0
25 77 467.0
30 86 547.0
35 95 637.0
40 104 737.0
45 113 849.0
50 122 973.0
55 131 1,110.0
60 140 1,261.0
65 149 1,426.0
70 158 1,607.0
75 167 1,804.0
80 176 2,019.0
85 185 2,252.0
90 194 2,504.0
95 203 2,777.0
100 212 3,071.0