T
Toshiba Error Codes
Inverter Mini-Splits & Air Conditioners ยท Japan
Prefixes: E=System/Sensor, F=Sensor/Protection, P=Protection, H=Status
E-Series (System/Sensor Errors)
| Code | Description | Possible Cause | Action |
|---|---|---|---|
| E01 | Indoor PCB failure | Indoor control board fault | Replace indoor PCB |
| E02 | Indoor/outdoor communication error | Communication line disconnected | Check signal wiring |
| E03 | Remote controller communication error | Remote signal fault | Check remote and receiver |
| E04 | Indoor fan motor error | Fan motor locked or abnormal | Check fan motor and wiring |
| E05 | Indoor thermistor fault | Room temperature sensor failure | Check room sensor resistance |
| E06 | Indoor coil sensor fault | Evaporator thermistor failure | Check coil temperature sensor |
| E07 | Drain sensor/pump fault | Drainage system error | Check drain line and float switch |
| E09 | Indoor EEPROM error | EEPROM data corrupted | Reset power; replace PCB if needed |
| E10 | Multi-indoor capacity error | Indoor capacity exceeds outdoor | Verify unit capacity matching |
| E15 | Outdoor PCB fault | Outdoor control board failure | Replace outdoor PCB |
| E16 | Compressor overcurrent | Compressor drawing excess current | Check compressor, charge, voltage |
| E17 | Outdoor fan motor fault | Fan motor error | Check outdoor fan motor and wiring |
| E18 | Outdoor coil sensor fault | Condenser thermistor failure | Check outdoor coil sensor |
| E19 | Outdoor ambient sensor fault | Outdoor temperature sensor failure | Check outdoor ambient sensor |
| E20 | Discharge temperature sensor fault | Discharge thermistor failure | Check discharge temperature sensor |
| E21 | High pressure protection | System high pressure exceeded | Check condenser, fan, charge |
| E22 | Compressor overheating | Compressor discharge temperature high | Check superheat, charge, airflow |
| E23 | Low pressure protection | System low pressure detected | Check for leaks, verify charge |
| E24 | Inverter overcurrent | IPM module overcurrent | Check inverter module and compressor |
| E27 | Outdoor EEPROM error | Outdoor EEPROM corrupted | Reset power; replace outdoor PCB |
| E28 | DC voltage abnormal | Inverter DC bus fault | Check power supply, rectifier |
| E31 | Heat sink temperature high | Inverter overheating | Check outdoor unit ventilation |
No matching error codes found
Try a different search term or browse the categories above.
Toshiba Troubleshooting Tips
Before Calling for Service
- Turn off unit, wait 5 minutes, then restart - some errors auto-reset
- Check and clean air filters - many errors caused by restricted airflow
- Verify power supply voltage is within specification
- Check circuit breaker and disconnect switch
- Note the exact error code and when it occurs for technician