H

Haier Error Codes

Inverter Mini-Splits & Air Conditioners ยท China

Prefixes: E=System/Sensor, F=Sensor/Protection, P=Protection, H=Status

E-Series (System/Sensor Errors)

Code Description Possible Cause Action
E0 EEPROM parameter error EEPROM data corrupted Reset power; replace board if persists
E1 Indoor/outdoor communication error Communication line fault Check signal wiring and connectors
E2 Zero crossing error Power supply issue Check power supply stability
E3 Fan speed error Indoor fan speed abnormal Check fan motor and circuit
E4 Room temperature sensor fault T1 sensor open/short Check room sensor
E5 Evaporator sensor fault T2 sensor open/short Check evaporator sensor
E6 Outdoor sensor fault Outdoor thermistor failure Check outdoor coil sensor
E7 Humidity sensor fault Humidity sensor failure Check and replace humidity sensor
E8 Address error Unit address conflict Check and reset unit addresses

F-Series (Sensor/Protection Codes)

Code Description Possible Cause Action
F1 Ambient temperature sensor fault Outdoor ambient sensor failure Check outdoor ambient sensor
F2 Condenser sensor fault Condenser thermistor failure Check condenser sensor
F3 Discharge sensor fault Discharge thermistor failure Check discharge temperature sensor
F4 Suction sensor fault Suction line sensor failure Check suction temperature sensor

P-Series (Protection Codes)

Code Description Possible Cause Action
P0 IPM protection Inverter module fault Check IPM module and compressor
P1 Voltage protection Supply voltage abnormal Check power supply voltage
P2 Compressor overheating Compressor top temperature high Check charge, superheat, airflow
P3 High current protection System overcurrent Check compressor and wiring
P4 Inverter drive error Drive board fault Check inverter drive board
P5 Fan motor fault Outdoor DC fan error Check outdoor fan motor

Haier Troubleshooting Tips

Before Calling for Service

  • Turn off unit, wait 5 minutes, then restart - some errors auto-reset
  • Check and clean air filters - many errors caused by restricted airflow
  • Verify power supply voltage is within specification
  • Check circuit breaker and disconnect switch
  • Note the exact error code and when it occurs for technician