XW60K
XW Series • HVAC Controller
Quick Info
Output Functions
Air handling unit controller with economizer and staging
Technical Specifications
Display & Interface
| Display Type | LCD |
| Display Digits | 4 |
| Buttons | 6 |
| LED Indicators | Fan, Cool1, Cool2, Heat, Econ, Alarm |
Power Supply
| Voltage | 230V AC |
| Voltage Range | 100-240V AC |
| Frequency | 50/60Hz |
| Power Consumption | 6VA |
Sensor Inputs
| Probe Inputs | 5 |
| Probe Type | NTC 10K / 0-10V |
| Temp Range | -40 to 80°C |
| Accuracy | ±0.3°C |
Relay Outputs
| Relay Outputs | 6 |
| Relay Rating | 8A/250VAC |
Physical
| Panel Size | 96x96 mm |
| Depth | 75 mm |
| IP Rating | IP65 (front) |
| Weight | 200 g |
Operating Conditions
| Operating Temp | -10 to 55°C |
| Storage Temp | -25 to 70°C |
Wiring Terminals
| Terminal | Function | Type | Wire Color |
|---|---|---|---|
| L | Power L | Input |
brown
|
| N | Power N | Input |
blue
|
| Pb1 | Return Air | Input |
NTC
|
| Pb2 | Supply Air | Input |
NTC
|
| Pb3 | Outside Air | Input |
NTC
|
| Pb4 | Mixed Air | Input |
NTC
|
| AI1 | CO2 Sensor | Input |
0-10V
|
| DI1 | Occupancy | Input |
gray
|
| DI2 | Filter Status | Input |
gray
|
| R1 | Supply Fan | Output |
black
|
| R2 | Cool Stage 1 | Output |
black
|
| R3 | Cool Stage 2 | Output |
black
|
| R4 | Heat Stage 1 | Output |
black
|
| R5 | Economizer Damper | Output |
green
|
| R6 | Alarm | Output |
red
|
| AO1 | Damper 0-10V | Output |
purple
|
| A/B | RS485 | Comm |
yellow/green
|
Important: Always disconnect power before wiring. Verify terminal numbers with the actual controller label before connecting.
Parameter Settings
| Code | Parameter | Range | Default | Description |
|---|---|---|---|---|
| SPC | Cooling Setpoint | 18 to 30 | 24 °C | Supply air cooling SP |
| SPH | Heating Setpoint | 15 to 25 | 20 °C | Supply air heating SP |
| dBC | Cool Deadband | 1 to 5 | 2 °C | Cooling neutral zone |
| dBH | Heat Deadband | 1 to 5 | 2 °C | Heating neutral zone |
| ECO | Economizer Enable | 0-1 | 1 | 0=Off, 1=On |
| EOT | Economizer OA Temp | 10 to 25 | 18 °C | Max OA temp for free cooling |
| CSd | Stage Delay | 1 to 30 | 5 min | Delay between cooling stages |
| FAN | Fan Mode | 0-2 | 1 | 0=Off, 1=Auto, 2=Continuous |
| OCC | Occupancy Mode | 0-2 | 1 | 0=Unoccupied, 1=Occupied, 2=Scheduled |
Error Codes
Solution: Check RA sensor
Solution: Check SA sensor
Solution: Check OA sensor
Solution: Replace air filter
Solution: Check fan motor, belt
Solution: MA temp too low
Frequently Asked Questions
Uses outside air for free cooling when OA temp is below EOT
Connect CO2 sensor to AI1, damper modulates based on CO2 level
Alternative Models (Cross Reference)
Manufacturer Information
Brand: Dixell
Country: Italy
Parent: Emerson Climate Technologies