LAE

BR60-40

BR Series • Refrigeration Controller

BR60-40

Quick Info

Type Refrigeration
Application Blast Chiller
Probe Inputs 4
Relay Outputs 4
Communication RS485 Modbus RTU / USB
Panel Size 96x96 mm

Output Functions

R1 Compressor
R2 Defrost
R3 Fan
R4 Alarm

Blast chiller and shock freezer controller with HACCP logging

Technical Specifications

Display & Interface

Display Type LCD
Display Digits Graphic
Buttons 6
LED Indicators Chill, Freeze, Hold, Alarm

Power Supply

Voltage 230V AC
Voltage Range 100-240V AC
Frequency 50/60Hz
Power Consumption 6VA

Sensor Inputs

Probe Inputs 4
Probe Type NTC / PT1000
Temp Range -55 to 150°C
Accuracy ±0.3°C

Relay Outputs

Relay Outputs 4
Relay Rating 8A/250VAC

Physical

Panel Size 96x96 mm
Depth 80 mm
IP Rating IP54 (front)
Weight 280 g

Operating Conditions

Operating Temp -10 to 55°C
Storage Temp -25 to 65°C

Wiring Terminals

Terminal Function Type Wire Color
1-2 Power 230VAC Input
brown/blue
3-4 Room Probe Input
yellow/white
5-6 Evaporator Probe Input
green/white
7-8 Core Probe 1 Input
orange/white
9-10 Core Probe 2 Input
violet/white
11 Door Switch Input
gray
12 External Start Input
gray
13 DI Common Input
black
14-15 RS485 Comm
orange/yellow
16 USB Comm
N/A
17-18 Compressor Output
black
19-20 Defrost Output
red
21-22 Fan Output
blue
23-24 Alarm Output
gray

Important: Always disconnect power before wiring. Verify terminal numbers with the actual controller label before connecting.

Parameter Settings

Code Parameter Range Default Description
CHt Chill Target -5 to 10 3 °C Chill cycle end temperature
CHd Chill Duration 10 to 240 90 min Maximum chill time
FRt Freeze Target -30 to -10 -18 °C Freeze cycle end temperature
FRd Freeze Duration 30 to 360 180 min Maximum freeze time
HO Hold Temp -25 to 10 -18 °C Holding temperature after cycle
PR Product Probe 1-3 3 Core temperature probe number

Error Codes

E1 Room probe fault

Solution: Check room probe

E2 Evap probe fault

Solution: Check evaporator probe

E3 Core probe 1 fault

Solution: Check product probe

E4 Core probe 2 fault

Solution: Check second probe

TO Time out alarm

Solution: Cycle exceeded max time

dO Door open

Solution: Close door

HA HACCP alarm

Solution: Check food safety records

Frequently Asked Questions

Alternative Models (Cross Reference)

Dixell XB570L Carel MCHRTF Eliwell EWTQ

Manufacturer Information

Brand: LAE

Country: Italy

Visit Manufacturer Website