XR80CX
XR Series • Refrigeration Controller
Quick Info
Output Functions
Specialized controller for milk tank refrigeration
Technical Specifications
Display & Interface
| Display Type | LED |
| Display Digits | 4 |
| Buttons | 4 |
| LED Indicators | Cooling, Agitator, Wash, Alarm |
Power Supply
| Voltage | 230V AC |
| Voltage Range | 110-230V AC |
| Frequency | 50/60Hz |
| Power Consumption | 5VA |
Sensor Inputs
| Probe Inputs | 2 |
| Probe Type | NTC / PT1000 |
| Temp Range | -50 to 110°C |
| Accuracy | ±0.3°C |
Relay Outputs
| Relay Outputs | 4 |
| Relay Rating | 8A/250VAC |
Physical
| Panel Size | 32x74 mm |
| Depth | 65 mm |
| IP Rating | IP65 (front) |
| Weight | 120 g |
Operating Conditions
| Operating Temp | 0 to 55°C |
| Storage Temp | -25 to 60°C |
Wiring Terminals
| Terminal | Function | Type | Wire Color |
|---|---|---|---|
| L | Power L | Input |
brown
|
| N | Power N | Input |
blue
|
| Pb1 | Milk Probe | Input |
red/white
|
| Pb2 | Surface Probe | Input |
red/white
|
| DI1 | Level Switch | Input |
gray
|
| DI2 | Wash Button | Input |
gray
|
| R1 | Compressor | Output |
black
|
| R2 | Agitator | Output |
blue
|
| R3 | Wash Pump | Output |
green
|
| R4 | Alarm | Output |
red
|
Important: Always disconnect power before wiring. Verify terminal numbers with the actual controller label before connecting.
Parameter Settings
| Code | Parameter | Range | Default | Description |
|---|---|---|---|---|
| SEt | Setpoint | 0 to 10 | 4 °C | Milk temperature setpoint |
| Hy | Differential | 0.1 to 5 | 0.5 °C | Switching differential |
| Aon | Agitator On | 0 to 60 | 2 min | Agitator run time |
| AoF | Agitator Off | 0 to 60 | 15 min | Agitator pause time |
| WAS | Wash Mode | 0=Manual, 1=Auto | 0 | Wash cycle mode |
| AL | Low Alarm | 0 to SET | 2 °C | Freezing alarm |
| AH | High Alarm | SET to 15 | 8 °C | Warm milk alarm |
Error Codes
Solution: Check milk temperature probe
Solution: Check surface probe
Solution: Milk temp below safe level
Solution: Milk not cooling properly
Frequently Asked Questions
Runs cyclically based on Aon/AoF settings to prevent cream separation
Automated CIP (Clean-In-Place) cycle for tank cleaning
Alternative Models (Cross Reference)
Manufacturer Information
Brand: Dixell
Country: Italy
Parent: Emerson Climate Technologies