Quick Stats

Capacity 18,500 BTU/h
Power 5,422 W (~7.27 HP)
Refrigerant R32
Type DC Inverter
Application AC

Technical Specifications

Performance

Cooling Capacity 18,500 BTU/h
Cooling Capacity (W) 5,422 W
Displacement 50.3 cc
Application AC

Electrical

Voltage 220-240V/50Hz
Phase 1-Phase
RLA (Running Load Amps) 7.1 A
LRA (Locked Rotor Amps) A

Physical

Weight 12.5 kg
Oil Charge 450 cc
Oil Type POE

Refrigerant

Primary Refrigerant R32
Compressor Type DC Inverter

Oil Compatibility & Lubrication

Oil Specifications

Required Oil Type POE
Full Name Polyol Ester (POE)
Viscosity Grades ISO VG 32, 46
Recommended ISO VG 32
Factory Charge 450 cc

Compatible Oil Brands

  • Emkarate RL32-3MAF
  • SUNISO 3GS

Important Warnings for R32

  • • R-32 is mildly flammable (A2L) - avoid open flames
  • • POE oil absorbs moisture - minimize air exposure
  • • Lower viscosity preferred due to better miscibility

Oil Return: Good oil return characteristics due to excellent miscibility

General Oil Guidelines

! Never mix MO (Mineral) and POE oils - causes chemical breakdown
💧 POE absorbs moisture - keep container sealed, minimize air exposure
Check oil level through sight glass after 24 hours of operation

Installation Guidelines

1

Ensure the system is properly evacuated before charging with R32 refrigerant.

2

Use POE oil only. Oil charge: 450 cc.

3

Breaker size recommendation: 9 A minimum (based on RLA × 1.25).

4

Wire size should be rated for 7.1 A continuous load at 220-240V/50Hz.

Recommended Accessories

Start Capacitor

For high starting torque applications

Run Capacitor

Improves efficiency and power factor

Overload Protector

Thermal protection for motor

Start Relay

PTC or current relay for motor starting

Manufacturer Information

Brand: Hitachi

Country: Japan

Visit Manufacturer Website